ATO 80V Blade Fuse

Explore the TONFUL Electric ATO-style blade fuse range listed for 80V DC, with six current options from 10A to 40A. Compare the selected part, blade dimensions and circuit-protection requirements before ordering.

  • Six listed current options: 10A, 15A, 20A, 25A, 30A and 40A.
  • 80V DC is a voltage listing, not a universal circuit compatibility guarantee.
  • Review current-time performance, interrupting capacity and holder fit.
  • Original material and certification wording is flagged for confirmation below.
Inquire about this product

Overview

This page brings together the six ATO 80V fuse options shown in the existing product range. Each option needs to be checked against the circuit voltage, operating current, available fault current, holder geometry and the selected part’s documentation. The listing does not establish suitability for an EV traction battery or another high-energy circuit.

Features

  • Blade-terminal format: compare the illustrated body and blade geometry with the intended fuse holder.
  • Six current options: the source lists 10A, 15A, 20A, 25A, 30A and 40A.
  • Rating identification: select by the approved part number and rating, not housing color alone.
  • Documentation-led selection: request the exact part’s voltage, current-time characteristic, interrupting rating and temperature information.

Technical Specifications

ParameterSource Listing / Confirmation Required
Product familyATO-style blade fuse; listed 80V range
Listed voltage80 VDC — confirm the exact part and test documentation
Listed current options10 A, 15 A, 20 A, 25 A, 30 A and 40 A
Interrupting ratingOriginal page lists 1000 A at 80 VDC; request part-specific confirmation and test conditions
Terminal materialSource conflict: marketing copy says zinc alloy; specification chart says tinned copper. Confirm the exact construction
Housing & temperatureOriginal wording is inconsistent (PC/PA66 versus “NL”). Request the material grade and operating/derating data
ComplianceOriginal page names SAE J2077, ISO 8820 and UL 248. These references do not establish certification for every option

The original page contains conflicting material descriptions and broad certification claims. These are not silently treated as verified performance. Request a datasheet and applicable reports for the exact part before approval.

10A 80V ATO blade fuse pair, original color and geometry retained
10A · 80V
15A 80V ATO blade fuse pair, original color and geometry retained
15A · 80V
20A 80V ATO blade fuse pair, original color and geometry retained
20A · 80V
25A 80V ATO blade fuse pair, original color and geometry retained
25A · 80V
30A 80V ATO blade fuse pair, original color and geometry retained
30A · 80V
40A 80V ATO blade fuse pair, original color and geometry retained
40A · 80V

Dimension

The source drawing is reproduced in high definition below. All dimensions are in millimeters and remain subject to the selected part drawing and tolerances.

Drawing itemSource dimension (mm)
Front-view body width19.3
Overall height19.7
Blade protrusion6.5
Blade width5.2
Bottom-view span14.70
Side-view body thickness5.2
Side-view blade thickness3.8
ATO blade fuse dimension drawing: 19.3, 19.7, 6.5, 5.2, 14.70, 5.2 and 3.8 mm

Selection Guide

Provide circuit voltage and whether it is DC, normal and transient current, available fault current, ambient temperature and the holder reference. Confirm the required time-current characteristic, interrupting capacity and mechanical fit with the exact fuse documentation. A higher voltage number alone does not make a fuse an approved replacement.

For replacement or maintenance, follow the equipment manufacturer’s specified fuse and isolation procedures. Do not increase the current rating to address repeated fuse operation; have the underlying fault assessed by qualified personnel.

Applications

The original application collage depicts vehicles, marine equipment, fuse panels and related systems. It illustrates enquiry contexts, not confirmed compatibility. Discuss only circuits whose complete requirements match the selected fuse and holder; no blanket main-battery, solar-storage or traction-system claim is made.

Original application collage remade without brand logos or website text

Ordering Information

Send the exact current option, required DC voltage, part drawing or holder reference, quantity and destination. Include current-time and interrupting requirements, operating conditions, documentation and packaging preferences for review.

Request an ATO 80V fuse quote or email ivan@tonful.com.

Buyer Support

Service Consultation — high-definition illustrative image without branding
Service Consultation
Share circuit, holder and documentation requirements so the selected fuse can be reviewed.
Product Recommendations — high-definition illustrative image without branding
Product Recommendations
Compare the exact fuse ratings and construction against the assembly requirements.
Installation Information — high-definition illustrative image without branding
Installation Information
Request the selected product instructions and follow equipment-specific maintenance procedures.
Logistics Support — high-definition illustrative image without branding
Logistics Support
Confirm unit packs, cartons, destination and shipping terms in the quotation.

Workshop & Inspection Images

The six original workshop and laboratory scenes are retained as high-definition illustrative reconstructions without logos or website text. They do not verify ownership of a facility, production capacity or certification.

Illustrative workshop and inspection scene 1 — original image content retained
Workshop and inspection scene 1 — illustrative reconstruction.
Illustrative workshop and inspection scene 2 — original image content retained
Workshop and inspection scene 2 — illustrative reconstruction.
Illustrative workshop and inspection scene 3 — original image content retained
Workshop and inspection scene 3 — illustrative reconstruction.
Illustrative workshop and inspection scene 4 — original image content retained
Workshop and inspection scene 4 — illustrative reconstruction.
Illustrative workshop and inspection scene 5 — original image content retained
Workshop and inspection scene 5 — illustrative reconstruction.
Illustrative workshop and inspection scene 6 — original image content retained
Workshop and inspection scene 6 — illustrative reconstruction.

Documentation Review

The five existing documentation symbols below are retained unchanged to preserve the original image inventory. Their presence is not proof that the exact fuse has those approvals; request part-specific certificates and reports.

Existing documentation symbol 1 — applicability must be confirmedExisting documentation symbol 2 — applicability must be confirmedExisting documentation symbol 3 — applicability must be confirmedExisting documentation symbol 4 — applicability must be confirmedExisting documentation symbol 5 — applicability must be confirmed

Buyer Questions

Can an 80V fuse replace any 32V fuse?

Not automatically. The DC voltage rating, time-current characteristic, interrupting rating, dimensions, holder and equipment requirements all need to match the approved replacement specification.

Are the material descriptions consistent?

No. The source says zinc alloy in the copy and tinned copper in the chart; it also uses different housing descriptions. Confirm the exact part’s material specification.

Are all listed standards confirmed certifications?

No. The original standard names and documentation symbols are not accepted as proof of approval for every current option. Request the applicable model-specific report.

Can I request branded packaging?

Send artwork, unit-pack quantities, carton requirements and any assortment proposal for quotation. Product images in this draft intentionally contain no TONFUL logo or website.

滚动至顶部