Waterproof Quick Branch Connector

Waterproof Quick Branch Connector

Connect parallel landscape-lighting branches with TONFUL JW1080 and JW1081 quick branch connectors. Match main and branch wire sizes and insulation diameters, then confirm the approved voltage, installation method and environmental requirements.

  • Branch connection to the main lighting wire
  • JW1080 and JW1081 main-wire options
  • Shared 14–20 AWG branch-wire reference

Inquire about this product

Send your requirements, we will quote for you within 12 hours

Tel:+8613655777486

Overview

Connect parallel landscape-lighting branches with TONFUL JW1080 and JW1081 quick branch connectors. Match main and branch wire sizes and insulation diameters, then confirm the approved voltage, installation method and environmental requirements.

Features

  • Branch connection to the main lighting wire
  • JW1080 and JW1081 main-wire options
  • Shared 14–20 AWG branch-wire reference
  • Wire-jacket diameter limits are part of selection

Technical Specifications

Parameter Specification
Original maximum voltage reference 600 V; confirm approved operating conditions
Original maximum load power reference 500 W; confirm applicable circuit conditions
Original direct-burial limit Below 40 V, with bolts positioned underneath; verify approved installation instructions
JW1080 main wire 12–18 AWG; one-lead insulation diameter no more than 5 mm
JW1081 main wire 8–18 AWG; one-lead insulation diameter no more than 7 mm
Branch wire, both models 14–20 AWG; one-lead insulation diameter no more than 4.2 mm

Confirm the model, installation conditions and required documentation before approving an order.

Dimension

No mechanical drawing was supplied. The table below preserves original wire-jacket fit limits; request a model-specific drawing for overall dimensions.

Model Main wire AWG Main one-lead diameter limit Branch wire AWG Branch one-lead diameter limit
JW1080 12–18 0.2 in / 5 mm 14–20 0.165 in / 4.2 mm
JW1081 8–18 0.28 in / 7 mm 14–20 0.165 in / 4.2 mm

No dimensioned mechanical drawing or IP rating was supplied on the original page. Request the JW1080 or JW1081 drawing and environmental documentation before approval. The original artwork’s PATENT 2023 claim is not reproduced without a supporting patent reference.

Selection Guide

Check wire sizes and the actual jacket diameter of each lead, including SPT-2 cable construction. With power isolated, follow the approved connector installation and sealing instructions. The below-40-V direct-burial reference is distinct from the original maximum voltage reference and must not be extrapolated to mains-voltage burial.

Applications

The original product is intended for parallel outdoor lighting connections. Use the illustration as an application reference only; confirm environmental approval, cable compatibility and installation conditions for the exact model.

Ordering Information

Send the complete JW1080 / JW1081 model reference, conductor sizes and count, application, quantity and required documents. Include sample, inspection and packaging preferences.

Contact TONFUL Electric to confirm product selection and quotation details.

Inquire about this product

Product images are high-definition illustrative recreations of the original photos. Verify construction against the approved drawing or sample.